A complete fictional record pack showing scope, observations, evidence gaps and follow-up.

SIMULATED EXAMPLE — not a real property, client case, certificate or actual App export. The property reference, people, dates, evidence IDs and outcomes below are invented for teaching. No supporting photos or trade reports exist for this example. It demonstrates a recording method, not an assessment that a property meets the law.
Use the blank worksheet

1. Cover record and scope

Reference: DEMO-001 · Fictional two-bedroom apartment, Victoria
Recorded: 20 October 2026, 10:00–10:45 · Demonstration recorder
Purpose: Organise records before a proposed rental advertisement
Version: 1.1, follow-up added 23 October 2026

Scope: Accessible rooms and visible fixtures only. No roof-space access, destructive investigation, electrical testing or engineering assessment. The record does not authorise advertising or occupancy.

2. Summary that keeps uncertainty visible

Open items: bedroom window latch fault; bathroom damp cause unresolved; electrical report not supplied. These stay open until appropriate evidence and review are recorded. The observations below are not pass/fail determinations.

CategoryIllustrative observation / recordLimit or next step
BathroomsBAS-01: washbasin and shower photographed; water observed at both.Shower rating document not supplied; confirm specification.
Electrical safetyELE-01: request for electrician’s report logged.Not assessed. Obtain appropriate professional evidence.
HeatingHEAT-01: fixed unit visible in main living room; model label recorded.Specification and technical condition not established by this visit.
KitchenKIT-01: sink and stovetop visible; no appliance test recorded.Operation not checked; arrange appropriate checks.
LaundryLAU-01: laundry cupboard photographed.Connection performance not tested.
LightingLIGHT-01: daytime room photos recorded.Artificial-light operation not recorded; follow up.
LocksLOCK-01: entry lock photographed from both sides.Mechanism and any applicable exception still to be confirmed.
Mould and dampDAMP-01: dark patch on bathroom ceiling beside fan.Cause unknown. Request suitable assessment; remain open.
Structural soundnessSTRUCT-01: accessible rooms viewed.No technical structural assessment; concealed elements not inspected.
ToiletsWC-01: toilet location photographed.Drainage connection evidence not reviewed.
VentilationVENT-01: bathroom grille visible.No ventilation performance or code assessment.
Vermin proof binsBIN-01: common-area waste station identified.Shared arrangements and lid condition to be recorded.
WindowsWIN-01: bedroom 2 latch did not hold in closed position during safe operation.Issue recorded; arrange repair and recheck.
Window coveringsCOVER-01: bedroom coverings photographed closed.Privacy and light observations need room-specific notes.
Window covering anchorsCORD-01: corded blind and anchor location photographed.Safety not established from photo alone; check uncertainty with a suitable person.

3. Evidence index

In a real record each reference points to a retained source file. For this simulated pack the references are illustrative only; do not copy them into a real inspection.

WIN-01: observation

Example file name: DEMO001_2026-10-20_bed2_latch_01.jpg. Caption: “Bedroom 2, east window, latch returned to open position when released.” Pair a room-context image with a close-up and a written observation. A close-up alone may not identify which window it concerns.

DAMP-01: uncertain cause

Caption: “Dark patch above bathroom fan, approximately hand-sized; cause not determined.” Record location and visible extent. Avoid replacing that with “condensation only” or “structural mould” without evidence that supports the diagnosis.

4. Action and follow-up register

Item / ownerAction and targetDated follow-upStatus
WIN-01 / demonstration managerArrange latch repair; target 22 October.23 October: simulated repair record WIN-02 received; recorder observed latch holding during safe operation, noted in WIN-03. Original finding retained.Specific latch issue recorded as resolved in this fictional example; no whole-property conclusion.
DAMP-01 / demonstration managerRequest assessment of cause and appropriate work.23 October: assessment requested, no report received.Open. A booking is not evidence of resolution.
ELE-01 / demonstration managerObtain electrician’s report and outstanding-work details.23 October: no document supplied.Not assessed. Do not mark as compliant.

5. Review and handover

Review note, 23 October: “This pack records one completed follow-up and several evidence gaps. Refer outstanding matters for appropriate assessment. Keep the property’s advertising/occupancy decision separate from this record and obtain advice where needed.”

A useful handover includes the original observations, linked evidence, unresolved-item list, next responsible person and a dated review. Keep versions together so a later reader can tell what was known at each stage.